superior Dianeal PD-1 Generic Name: Sodium chloride, sodium lactate, calcium chloride, magnesium chloride and dextrose Dosage Form: injection, solution Overview Side Effects Professional Reviews Q & A More Pricing & Coupons Dianeal PD-1 Peritoneal Dialysis Solution AMBU-FLEX III Container For Peritoneal Dialysis For intraperitoneal administration only Dianeal PD-1 Description Dianeal PD-1 peritoneal dialysis solutions in AMBU-FLEX III containers with a flanged port are sterile, nonpyrogenic solutions for intraperitoneal administration only. They contain no bacteriostatic or antimicrobial agents or added buffers. Composition, calculated osmolarity, pH and ionic concentrations are shown in Table 1. Potassium is omitted from DIANEAL solutions because dialysis may be performed to correct hyperkalemia. In situations in which there is a normal serum potassium level or hypokalemia, the addition of potassium chloride (up to a concentration of 4 mEq/L) may be indicated to prevent severe hypokalemia. Addition of potassium chloride should be made after careful evaluation of serum and total body potassium and only under the direction of a physician. Frequent monitoring of serum electrolytes is indicated. The osmolarities shown in Table 1 are calculated values. As an example, measured osmolarity by freezing point depression determination of Dianeal PD-1 peritoneal dialysis solution with 1.5% dextrose is approximately 334 mOsmol/L, compared with measured values in normal human serum of 280 mOsmol/L. The plastic container is fabricated from a specially formulated polyvinyl chloride (PL 146 Plastic). The amount of water that can permeate from inside the container into the overwrap is insufficient to affect the solution significantly. Solutions in contact with the plastic container can leach out certain of its chemical components in very small amounts within the expiration period, e.g., di-2-ethylhexyl phthalate (DEHP), up to 5 parts per million; however, the safety of the plastic has been confirmed in tests in animals according to USP biological tests for plastic containers as well as by tissue culture toxicity studies. Slideshow Hives: The What, Where, And Why Of This Bizarre Skin Condition Dianeal PD-1 - Clinical Pharmacology Peritoneal dialysis is a procedure for removing toxic substances and metabolites normally excreted by the kidneys, and for aiding in the regulation of fluid and electrolyte balance. The procedure is accomplished by instilling peritoneal dialysis fluid through a conduit into the peritoneal cavity. With the exception of lactate, present as a bicarbonate precursor, electrolyte concentrations in the fluid have been formulated to attempt to normalize plasma electrolyte concentrations resulting from osmosis and diffusion across the peritoneal membrane (between the plasma of the patient and the dialysis fluid). Toxic substances and metabolites, present in high concentrations in the blood, cross the peritoneal membrane into the dialyzing fluid. Dextrose in the dialyzing fluid is used to produce a solution hyperosmolar to the plasma, creating an osmotic gradient which facilitates fluid removal from the patient s plasma into the peritoneal cavity. After a period of time (dwell time), the fluid is drained by gravity from the cavity. Indications and Usage for Dianeal PD-1 Peritoneal dialysis is indicated for patients in acute or chronic renal failure when nondialytic medical therapy is judged to be inadequate (Vaamonde and Perez 1977). It may also be indicated in the treatment of certain fluid and electrolyte disturbances, and for patients intoxicated with certain poisons and drugs (Knepshield et al. 1977). However, for many substances other methods of detoxification have been reported to be more effective than peritoneal dialysis (Vaamonde and Perez 1977; Chang 1977). Contraindications None known. Warnings Peritoneal dialysis should be done with great care, if at all, in patients with a number of abdominal conditions including disruption of the peritoneal membrane or diaphragm by surgery or trauma, extensive adhesions, bowel distention, undiagnosed abdominal disease, abdominal wall infection, hernias or burns, fecal fistula or colostomy, tense ascites, obesity, and large polycystic kidneys (Vaamonde and Perez 1977). Other conditions include recent aortic graft replacement and severe pulmonary disease. When assessing peritoneal dialysis as the mode of therapy in such extreme situations, the benefits to the patient must be weighed against the possible complications. An accurate fluid balance record must be kept and the weight of the patient carefully monitored to avoid over or under hydration with severe consequences including congestive heart failure, volume depletion, and shock. Excessive use of Dianeal PD-1 peritoneal dialysis solution with 3.5% or 4.25% dextrose during a peritoneal dialysis treatment can result in significant removal of water from the patient. In acute renal failure patients, plasma electrolyte concentrations should be monitored periodically during the procedure. Stable patients undergoing maintenance peritoneal dialysis should have routine periodic evaluation of blood chemistries and hematologic factors, as well as other indicators of patient status. Not for use in the treatment of lactic acidosis. Potassium is omitted from Dianeal PD-1 solutions because dialysis may be performed to correct hyperkalemia. Addition of potassium chloride should be made after careful evaluation of serum and total body potassium and only under the direction of a physician. The use of 5 liters of dialysis solution is not indicated in a single exchange. Refer to manufacturer s directions accompanying drugs to obtain full information on additives. If the resealable rubber plug on the medication port is missing or partially removed, do not use product if medication is to be added. After removing overwrap, check for minute leaks by squeezing container firmly. If leaks are found, discard the solution because the sterility may be impaired. Freezing of solution may occur at temperatures below 0 C (32 F). Do not flex or manipulate container when frozen. Allow container to thaw naturally in ambient conditions and thoroughly mix contents by shaking. Precautions Aseptic technique must be used throughout the procedure and at its termination in order to reduce the possibility of infection. If peritonitis occurs, the choice and dosage of antibiotics should be based upon the results of identification and sensitivity studies of the isolated organism(s) when possible. Prior to identification of the involved organism(s), broad-spectrum antibiotics may be indicated. Peritoneal dialysis solutions may be warmed in the overpouch to 37 C (98.6 F) to enhance patient comfort. However, only dry heat (for example, heating pad) should be used. Solutions should not be heated in water due to an increased risk of infection. Microwave ovens should not be used to heat solutions because there is a potential for damage to the solution container. Moreover, microwave oven heating may potentially cause overheating and/or non-uniform heating of the solution that may result in patient injury or discomfort. Significant losses of protein, amino acids and water soluble vitamins may occur during peritoneal dialysis. Replacement therapy should be provided as necessary. Pregnancy Teratogenic Effects Pregnancy Category C Animal reproduction studies have not been conducted with DIANEAL peritoneal dialysis solutions. It is also not known whether DIANEAL peritoneal dialysis solutions can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. DIANEAL peritoneal dialysis solutions should be given to a pregnant woman only if clearly needed. Do not administer unless solution is clear and seal is intact. Adverse Reactions Adverse reactions to peritoneal dialysis include mechanical and solution related problems as well as the results of contamination of equipment or improper technique in catheter placement. Abdominal pain, bleeding, peritonitis, subcutaneous infection around a chronic peritoneal catheter, catheter blockage, difficulty in fluid removal, and ileus are among the complications of the procedure. Solution related adverse reactions may include electrolyte and fluid imbalances, hypovolemia, hypervolemia, hypertension, hypotension, disequilibrium syndrome and muscle cramping. Dianeal PD-1 Dosage and Administration Dianeal PD-1 solutions are intended for intraperitoneal administration only. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. The mode of therapy (Intermittent Peritoneal Dialysis [IPD], Continuous Ambulatory Peritoneal Dialysis [CAPD], or Continuous Cyclic Peritoneal Dialysis [CCPD]), frequency of treatment, formulation, exchange volume, duration of dwell, and length of dialysis should be selected by the physician responsible for and supervising the treatment of the individual patient. To avoid the risk of severe dehydration and hypovolemia and to minimize the loss of protein, it is advisable to select the peritoneal dialysis solution with the lowest level of osmolarity consistent with the fluid removal requirements for that exchange. Peritoneal dialysis solutions may be warmed in the overpouch to 37 C (98.6 F) to enhance patient comfort. However, only dry heat (for example, heating pad) should be used. (See Directions for Use) The addition of heparin to the dialysis solution may be indicated to aid in prevention of catheter blockage in patients with peritonitis, or when the solution drainage contains fibrinous or proteinaceous material (Ribot et al. 1966). 1000 to 2000 USP units of heparin per liter of solution has been recommended for adults (Furman et al. 1978). For children, 50 units of heparin per 100 mL of dialysis fluid has been recommended (Irwin et al. 1981). Additives may be incompatible. Complete information is not available. Those additives known to be incompatible should not be used. Consult with pharmacist, if available. If, in the informed judgement of the physician, it is deemed advisable to introduce additives, use aseptic technique. Mix thoroughly when additives have been introduced. Do not store solutions containing additives. Intermittent Peritoneal Dialysis (IPD) For dialysis of acute renal failure patients and maintenance dialysis of chronic renal failure patients The cycle of instillation, dwell and removal of dialysis fluid is repeated sequentially over a period of hours (8 to 36 hours) as many times per week as indicated by the condition of the patient. For chronic renal failure patients, maintenance dialysis is often accomplished by periodic dialysis (3 to 5 times weekly) for shorter time periods (8 to 14 hours per session) (Mattocks and El-Bassiouni 1971). Continuous Ambulatory Peritoneal Dialysis (CAPD) and Continuous Cyclic Peritoneal Dialysis (CCPD) For maintenance dialysis of chronic renal failure patients In CAPD, 1.5 to 3.0 liters of dialysis solution (depending upon patient size) are instilled into the peritoneal cavity of adults and the peritoneal access device is then clamped (Kim et al. 1984; Twardowski and Janicka 1981; Twardowski and Burrows 1984). For children, 30 to 50 mL/kg body weight with a maximum of 2 liters has been recommended (Potter et al. 1981; Irwin et al. 1981). The solution remains in the cavity for dwell times of 4 to 8 hours during the day and 8 to 12 hours overnight. At the conclusion of each dwell period, the access device is opened, the solution drained and fresh solution instilled. The procedure is repeated 3 to 5 times per day, 6 to 7 days per week. Solution exchange volumes and frequency of exchange should be individualized for adequate biochemical and fluid volume control (Moncrief et al. 1982; Twardowski et al. 1983). The majority of exchanges will utilize 1.5% or 2.5% dextrose containing peritoneal dialysis solutions, with 3.5% or 4.25% dextrose containing solutions being used when extra fluid removal is required. Patient weight is used as the indicator of the need for fluid removal (Popovich et al. 1978). In CCPD, the patient receives 3 or 4 dialysis exchanges during the night which range from 2-1/2 to 3 hours dwell duration. Typically 1.5 to 2.0 liters of dialysis solution (depending upon patient size) are delivered each cycle by an automatic peritoneal dialysis cycler machine. After the last outflow during the night, an additional exchange is infused by the cycler machine into the peritoneum. The equipment is then disconnected from the patient, and the dialysate remains in the peritoneum for 14 to 15 hours during the day until the next nocturnal cycle (Diaz-Buxo et al. 1981). Combinations of 1.5% or 2.5% dextrose containing peritoneal dialysis solutions are usually used for the nighttime exchanges while 3.5% or 4.25% dextrose is used when extra fluid removal is required such as during the daytime exchange. Patient weight is used as the indicator of the need for fluid removal (Popovich et al. 1978) so therapy should be individualized according to the patient s need for ultrafiltration. It is recommended that adult patients being placed on chronic peritoneal dialysis or, in the case of pediatric patients, the selected caretaker, (as well as the patient, when suitable), should be appropriately trained in a program which is under the supervision of a physician. Training materials are available from Baxter Healthcare Corporation, Deerfield, IL 60015, USA to facilitate this training. How is Dianeal PD-1 Supplied Dianeal PD-1 peritoneal dialysis solutions in AMBU-FLEX III containers are available in nominal size flexible containers with fill volumes and dextrose concentrations as indicated in Table 1. All Dianeal PD-1 peritoneal dialysis solutions have overfills which are declared on container labeling. Exposure of pharmaceutical products to heat should be minimized. Avoid excessive heat. It is recommended the product be stored at room temperature (25 C/77 F): brief exposure up to 40 C (104 F) does not adversely affect the product. Directions for Use Use aseptic technique. For complete system preparation, see directions accompanying ancillary equipment. Peritoneal dialysis solutions may be warmed in the overpouch to 37 C (98.6 F) to enhance patient comfort. However, only dry heat (for example, heating pad) should be used. Solutions should not be heated in water due to an increased risk of infection. Microwave ovens should not be used to heat solutions because there is a potential for damage to the solution container. Moreover, microwave oven heating may potentially cause overheating and/or non-uniform heating of the solution that may result in patient injury or discomfort. To Open Tear overwrap down side at slit and remove solution container. Some opacity of the plastic due to moisture absorption during the sterilization process may be observed. This is normal and does not affect the solution quality or safety. If supplemental medication is desired, follow directions below before preparing for administration. Check for minute leaks by squeezing container firmly. To Add Medication Additives may be incompatible. If the resealable rubber plug on the medication port is missing or partially removed, do not use product if medication is to be added. Prepare medication site. Using a syringe with a 1 inch long 19 to 25 gauge needle, puncture resealable medication port and inject. Position container with ports up and evacuate the medication port by squeezing and tapping it. Mix solution and medication thoroughly. Preparation for Administration Place container on table or suspend from support (depending on technique). Remove protector from outlet port of container. Attach appropriate solution transfer set. Refer to complete directions in hardware manual and/or directions accompanying transfer set. Discard unused portion. REFERENCES Chang, T.M.S. 1977. Criteria, evaluation, and perspectives of various microencapsulated charcoal hemoperfusion systems. Dial and Transplant 6:50-53. Diaz-Buxo, J.A. et al. 1981. Continuous cyclic peritoneal dialysis: a preliminary report. Int Soc Artif Organs 81:157-161. Furman, K.l. et al. 1978. Activity of intraperitoneal heparin during peritoneal dialysis. Clin Nephrol 9:15-18. Irwin, M.A. et al. 1981. Continuous ambulatory peritoneal dialysis in pediatrics. AANNT J 8:11-13,44. Kim, D. et al. 1984. Continuous ambulatory peritoneal dialysis with three-liter exchanges: a prospective study. Peritoneal Dial Bull 4:82-85. Knepshield, J.H. et al. 1977. Dialysis of poisons and drugs - update. Trans Am Soc Artif Intern Organs 23:762-842. Mattocks, A.M. and El-Bassiouni, E.A. 1971. Peritoneal dialysis: a review. J Pharm Sci 60:1767-1782. Moncrief, J.W. et al. 1982. CAPD: Are three exchanges per day adequate? AANNT J 9:39-43. Popovich, R.P. et al. 1978. Continuous ambulatory peritoneal dialysis. Ann Intern Med 8:449-456. Potter, D.E. et al. 1981. Continuous ambulatory dialysis (CAPD) in children. Trans Am Soc Artif Intern Organs 27:64-67. Ribot, S. et al. 1966. Complications of peritoneal dialysis. Am J Med Sci 252:505-517. Vaamonde, C.A. and Perez, G.O. 1977. Peritoneal dialysis today. Kidney 10:31-36. Twardowski, Z.J. and Janicka, L. 1981. Three exchanges with a 2.5 liter volume for continuous ambulatory peritoneal dialysis. Kidney Int 20:281-284. Twardowski, Z.J. et al. 1983. High volume low frequency continuous ambulatory peritoneal dialysis. Kidney Int 23:64-70. Twardowski, Z.J. and Burrows, L. 1984. Two year experience with high volume, low frequency continuous ambulatory peritoneal dialysis. Peritoneal Dial Bull 4:S67. Table 1 Composition/100 mL Osmolarity (mOsmol/L) (calc) pH Ionic Concentration (mEq/L) How Supplied *Dextrose, Hydrous, USP Sodium Chloride, USP (NaCl) Sodium Lactate (C 3 H 5 NaO 3 ) Calcium Chloride, USP (CaCl 2 2H 2 O) Magnesium Chloride, USP (MgCl 2 6H 2 O) Sodium Calcium Magnesium Chloride Lactate Fill Volume (mL) Container Size (mL) Code NDC Dianeal PD-1 Peritoneal Dialysis Solution with 1.5% Dextrose 1.5 g 567 mg 392 mg 25.7 mg 15.2 mg 347 5.2 (4.0 to 6.5) 132 3.5 1.5 102 35 2000 5000 2000 5000 5B5136 5B5190 NDC 0941 0377 46 NDC 0941-0377-25 Dianeal PD-1 Peritoneal Dialysis Solution with 2.5% Dextrose 2.5 g 567 mg 392 mg 25.7 mg 15.2 mg 398 5.2 (4.0 to 6.5) 132 3.5 1.5 102 35 2000 2000 5000 2000 3000 5000 5B5146 5B5147 5B5191 NDC 0941 0383 46 NDC 0941-0383-47 NDC 0941-0383-25 Dianeal PD-1 Peritoneal Dialysis Solution with 4.25% Dextrose 4.25 g 567 mg 392 mg 25.7 mg 15.2 mg 486 5.2 (4.0 to 6.5) 132 3.5 1.5 102 35 2000 5000 3000 5000 5B5157 5B5192 NDC 0941 0379 47 NDC 0941-0379-25 Baxter, DIANEAL, AMBU-FLEX, and PL 146 are trademarks of Baxter International Inc. Baxter Healthcare Corporation Deerfield, IL 60015 USA Printed in USA Copyright 1981, 1982, 1983, 1984, 1989, Baxter Healthcare Corporation. All rights reserved. Dianeal PD-1 WITH DEXTROSE sodium chloride, sodium lactate, calcium chloride, magnesium chloride and dextrose injection, solution Product Information Product Type HUMAN PRESCRIPTION DRUG LABEL Item Code (Source) NDC:0941-0377 Route of Administration INTRAPERITONEAL DEA Schedule Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength Dextrose hydrous (dextrose) dextrose 1.5 g in 100 mL Sodium Chloride (sodium chloride) sodium chloride 567 mg in 100 mL Sodium Lactate (Sodium lactate) Sodium lactate 392 mg in 100 mL Calcium Chloride (calcium chloride) calcium chloride 25.7 mg in 100 mL Magnesium Chloride (magnesium chloride) magnesium chloride 15.2 mg in 100 mL Inactive Ingredients Ingredient Name Strength Water Packaging # Item Code Package Description 1 NDC:0941-0377-46 2000 mL (2000 MILLILITER) in 1 BAG 2 NDC:0941-0377-25 5000 mL (5000 MILLILITER) in 1 BAG Dianeal PD-1 WITH DEXTROSE sodium chloride, sodium lactate, calcium chloride, magnesium chloride and dextrose injection, solution Product Information Product Type HUMAN PRESCRIPTION DRUG LABEL Item Code (Source) NDC:0941-0379 Route of Administration INTRAPERITONEAL DEA Schedule Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength Dextrose hydrous (dextrose) dextrose 4.25 g in 100 mL Sodium Chloride (sodium chloride) sodium chloride 567 mg in 100 mL Sodium Lactate (sodium lactate) sodium lactate 392 mg in 100 mL Calcium Chloride (calcium chloride) calcium chloride 25.7 mg in 100 mL Magnesium Chloride (magnesium chloride) magnesium chloride 15.2 mg in 100 mL Inactive Ingredients Ingredient Name Strength Water Packaging # Item Code Package Description 1 NDC:0941-0379-47 2000 mL (2000 MILLILITER) in 1 BAG 2 NDC:0941-0379-25 5000 mL (5000 MILLILITER) in 1 BAG Dianeal PD-1 WITH DEXTROSE sodium chloride, sodium lactate, calcium chloride, magnesium chloride and dextrose injection, solution Product Information Product Type HUMAN PRESCRIPTION DRUG LABEL Item Code (Source) NDC:0941-0383 Route of Administration INTRAPERITONEAL DEA Schedule Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength Dextrose hydrous (dextrose) dextrose 2.5 g in 100 mL Sodium Chloride (sodium chloride) sodium chloride 567 mg in 100 mL Sodium Lactate (sodium lactate) sodium lactate 392 mg in 100 mL Calcium Chloride (calcium chloride) calcium chloride 25.7 mg in 100 mL Magnesium Chloride (magnesium chloride) magnesium chloride 15.2 mg in 100 mL Inactive Ingredients Ingredient Name Strength Water Packaging # Item Code Package Description 1 NDC:0941-0383-46 2000 mL (2000 MILLILITER) in 1 BAG 2 NDC:0941-0383-47 3000 mL (3000 MILLILITER) in 1 BAG 3 NDC:0941-0383-25 5000 mL (5000 MILLILITER) in 1 BAG Labeler - Baxter Healthcare Corporation Revised: 05/2006 Baxter Healthcare Corporation Next User Reviews Print this page Add to My Med List More about lvp solution Side Effects Support Group Pricing & Coupons 0 Reviews Add your own review/rating Drug class: intravenous nutritional products Consumer resources Icodextrin Intravenous (IV) Fluids Icodextrin Intraperitoneal (Advanced Reading) Professional resources Dextrose and Sodium Chloride Injection (FDA) Dextrose in Lactated Ringer's (FDA) Dextrose in Ringer's (FDA) Ringers (FDA) Other brands: Normosol-R , Plasma-Lyte 148 , Extraneal , Delflex , ... +2 more Related treatment guides Dehydration Peritoneal dialysis} FEATURED: CAR-T Cell Therapy Overview Mechanism of Action KTE-C19 Studies KTE-C19 Cancer Targets Adverse Events Manufacturing Drug Status Rx Availability Prescription only C Pregnancy Category Risk cannot be ruled out N/A CSA Schedule Not a controlled drug Manufacturer Baxter International Inc. Drug Class Intravenous nutritional products Related Drugs intravenous nutritional products cysteine , Novamine , Intralipid , fat emulsion Dehydration Normosol-R , Plasma-Lyte 148 , Isolyte S , More... Lvp solution Rating No Reviews - Be the first! No Reviews - Be the first! Not Rated - Be the first!} } it's vital
richly deserved Dianeal PD-1 pattern
EmoticonEmoticon